The maintenance time depends on the extraction pharmacological process. If the airtight extraction needs cooling water, After the steam vapor is cooled, it returns to the extraction tank to maintain circulation and temperature.
Designed pressure (MPa): —0.1
Working pressure(MPa): —0.09
Designed temp.(℃): 95
Working temp.(℃): 85
Media: Material liquid
Main applications
The multi-functional extraction and concentration heat reflux unit can be used for normal pressure, water decoction, wet soaking, heat reflux, forced circulation osmosis, aromatic oil extraction and organic solvent recovery in industries such as medicine and health care, pigments, food and beverage, animals and plants, and chemical industry.
Product display
Fruit vegetable extraction machine
Related parameters
Item | Concentrator | Extract tank | Back-flow liquid storage tank | Condenser | Cooler | ||||
Inside tank | Jacket | Inside tank | Jacket | Inside tank | Tube side | Shell side | Tube side | Shell side | |
Designed pressure (MPa) | —0.1 | 0.2 | —0.1 | 0.2 | —0.1 | —0.1 | 0.25 | —0.1 | 0.25 |
Working pressure(MPa) | —0.09 | 0.09 | —0.09 | 0.09 | —0.09 | —0.09 | 0.2 | —0.09 | 0.2 |
Designed temp.(℃) | 95 | 133 | 95 | 133 | Normal | 65 | Normal | 50 | Normal |
Working temp.(℃) | 85 | 117 | 85 | 117 | Normal | 60 | Normal | 45 | Normal |
Media | Material liquid | water | Material liquid | water | Material liquid | Material liquid | Cool water | Material liquid | Cool water |
Heat exchange area(M²) | 1.2 | 1.1 | 4.52 | 0.3 | |||||
Volum(L) | 200L | 200L | 180L | ||||||
Evaporate qty. | 100kg/H | Vacuum pump(anti-explosion) | SK0.8 | ||||||
Electric heating power(KW) | 24KW/380V | 16KW/380V | Material liquid pump | 1T/H |
Working principle
1. Such as water extraction: put the water into the extraction tank, start to supply the heat source to the interlayer, reduce the heat source after the tank boils, and keep the tank boiling. The maintenance time depends on the extraction pharmacological process. If the airtight extraction needs cooling water, After the steam vapor is cooled, it returns to the extraction tank to maintain circulation and temperature.
2. Such as alcohol extraction: first add the medicine and alcohol into the tank and seal it tightly, supply steam to the interlayer heat source, open the cooling water to reduce the supply of heat source when the tank reaches the required temperature, so that the rising vapor alcohol passes through the condenser and then turns into liquid alcohol and refluxes.
3. Recovery of olein: Add alcohol into the cylinder, turn on the cooling water for the steam, and then open the recovery valve
4. Oil extraction: first add the volatile oil and water into the extraction tank, open the circulation valve of the oil separator, adjust the bypass return valve, open the heat supply valve and turn on the cooling water to cool when the heat source valve reaches the volatilization temperature, and the cooled liquid medicine The height should be kept in the separator to separate them, and then the oil-water separator will be used alternately.